2-24 IntelliTouch/SecureTouch Guide
5 Connect the 2x5 female connector, on the serial output cable (See “Elo Part
Numbers” on page 79), to the 2x5 male connector at P2 on the controller.
Mount the DB9 female end of the cable in the position determined in step 2.
The serial cable connector shell must be grounded to satisfy safety agency
approvals, as the grounding protects the user in case a wiring fault develops
in the display. If the DB9 connector shell is not already grounded, attach the
ground wire supplied in the kit to one of the DB9s mounting screws and the
other end to chassis ground.
6 Adhere the metal plate labeled with the legend, “Touchscreen Interface”, to
the outside of the bulkhead-mounted DB9 connector. A similar plate (See
“Elo Part Numbers” on page 79) is also available with vertical labeling.
7 Label the monitor to indicate what IntelliTouch serial controller is installed
inside the display and include its jumper settings, if any.