Control Inputs
Analog command:
±10 Vdc 14 bit, 100 kOhm impedance, differential
Absolute Maximum Input Voltage Input: +/- 14 Vdc to ground or differential, including
drive enable
Digital Inputs: 5 on the EP-B and 16 on the EP-I and EP-P including the drive enable
input, 10 Vdc - 30 Vdc, 4.8 kohm impedance; current sourcing signal compatible (active
high); max input response time is 500 µs; optically isolated.
Input debounce: 0-2000 ms configured in PowerTools Pro
Control Outputs
Diagnostic Analog Outputs: (2) ±10 Vdc into 10 Kohm (single ended), short circuit proof
to ground, short circuit proof to ground, 10 bit, software selectable output signals
Digital Outputs: 3 on EP-B, 8 on the EP-I and EP-P, 150 mA max each, short circuit
proof, current source from 10 Vdc - 30 Vdc I/O power supply, 3.5 Vdc max supply to
output voltage drop @ 150 mA, opto-isolated
Motor temp sensor: Contact: 5 Vdc O.C. (tripped), 0.5 mA S.C. (normal)
Compatible with PTC thermistor with 1 kOhm resistance at trip point
Pulse Mode
Interface: Software selectable differential (RS422) or single ended (TTL Schmitt Trigger)
Maximum input frequency:
Differential - 1 MHz per channel; (4 million counts/second in quadrature),
0.5 µs minimum pulse width
Single ended - 500 kHz per channel; (2 million counts/second in quadrature),
1 µs minimum pulse width
Ratio Capabilities: 20 to 163,840,000 PPR
Single ended inputs have 1 kohm pull-up to 5 V
Encoder Output Signal
Differential line driver, RS-422 and TTL compatible
Scalable in one line increment resolution up to 2048 lines/rev of the motor (NT)
Shunt Resistor Capacity/
Regeneration Capacity
Energy storage available in bus caps:
EP202: 15 J @ 240 Vac, 30 J @ 120 Vac
EP204: 24 J @ 240 Vac, 63 J @ 120 Vac
EP206: 40 J @ 240 Vac, 104 J @ 120 Vac
EP204/EP206 External Shunt Control:
12 A peak, 2 kW max average power, 33 ohm minimum external resistor
Earth Leakage Current and RCD
Compatibility
25 mA AC and < 0.1 mA DC with 15 ft (4.6 m) CMDS motor power cable and NT-330
motor at 240 Vac. Leakage is higher with longer cables.
The EP drive is compatible with a Type A Residual current Detector (RCD) that allows
expected leakage currents.
Epsilon EP Series