Emerson ATCA-S201 Power Supply User Manual


 
RTM-ATCA-SXXX Overview
6806800H62B ATCAS201InstallationandUseGuide102
AMC slot B1
AMC slot B2
AMC slot B3
AMC slot B4
DDR2 DIMM
J23
J10
CPU
PCIe
Switch
SAS
10GbE
XAUI
ATCA-S201
JP1
JP2
J30
J32
J33
3 2 1
3 2 1
Figure 30 ATCA-S201 Jumper locations
9.4.2 Emergency flash recovery (factory reset)
The method described in this section explains a procedure to repair primary flash
contents that are blank, erased or corrupted. We advise against using this
emergency recovery procedure if the ATCA-S201 is functional, and management
communications can be conducted.
Upgrade firmware procedure
1. Remove the ATCA carrier the chassis (see 2.9, Removing the ATCA carrier
blade)
2. Locate header JP1, and move the jumper to the service setting. This causes the
blade to fetch firmware from the read-only factory flash.
3. Re-install the ATCA blade into the chassis and allow it to reboot.