Emerson ATCA-S201 Power Supply User Manual


 
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 14-1
Table 72. ATCA-S201 Sensor Data Records
Sensor UNR UC UNC LNC LC LNR ID String
1.0V 1.16 1.13 1.10 0.90 0.87 0.84 +1.0V
1.1V 1.27 1.24 1.21 0.99 0.99 0.91 +1.1V
1.2V 1.40 1.36 1.32 1.08 1.04 1.00 +1.2V
1.5V 1.75 1.70 1.65 1.35 1.30 1.25 +1.5V
1.8V 2.05 2.00 1.95 1.65 1.60 1.55 +1.8V
2.5V 2.90 2.80 2.70 2.30 2.20 2.10 +2.5V
3.3V 3.60 3.55 3.50 3.10 3.00 2.0 +3.3V
AMC Exit Temp 80 90 100 N/A N/A N/A
AMC exit
Temp
Zone-3 Exit 80 90 100 N/A N/A N/A Zone3-Exit
Inlet Temp 60 70 80 N/A N/A N/A Inlet Temp
Table 73. RTM-ATCA-SXXX Sensor Data Records
Sensor UNR UC UNC LNC LC LNR ID String
3.3V 3.60 3.50 3.45 3.15 3.10 3.00 +3.3V
5.0V 5.50 5.35 5.25 4.75 4.65 4.5 +5V
12V 13.60 13.40 13.00 11.00 10.60 10.400 +12V
Board Temp (LM75) 70 60 50 N/A N/A N/A Board Temp
Inlet Temp (LM60) 70 60 50 N/A N/A N/A Inlet Temp
The ATCA-S201 and the RTM-ATCA-SXXX include the standard FRU data records per
the IPMI Platform Management FRU Information Storage Definition, Board Info
Area. The ATCA-S201 and the RTM-ATCA-SXXX include additional FRU records as
defined in the PICMG 2.9 specification.
Table 74 ATCA-S201 Example FRU Data Records
Board Information ATCA-S201
Version 1
Language Code EN (English)
MFG date.time See note *1
Manufacturer Emerson
Product Name ATCA-S201
Serial Number 100LYMMssss (See note *2)
Part Number 0106826G01A
*1. Manufacturing time is defined as 'minutes since 1/1/96' in the IPMI FRU spec.
*2. Serial Number format: 102LYMSSSS
AAA = Assembly Number (102)
L =Location of manufacturer