Epson 3260 Printer User Manual


 
Environmental
Temperature
Operation:
5° to 35°C (41° to 95°F)
Operation (envelopts,
labels, or recycled paper):
15° to 25°C
Storage:
-20° to 55°C (-4° tto 131°F)
Humidity (without condensation):
Operation:
5% to 80% RH without condensation
Operation (envelopes,
labels, or recycled paper):
20% to 60% RH
Storage:
5% to 85% RH without condensation
Sufety approvals
Safety standards:
US model:
European model:
R.F.I.
UL1950 with D3, CSA22.2 No.950 with D3
EN 60950 (TUV), IEC 950 (SEMKO,
DEMKO, NEMKO, SETI)
US model:
European model:
FCC part 15 subpart B class B
Vfg243 VvDE0878 part 3, part 30),
EN55022 (CISPR PUB22) class B
Interface specifications
Your printer is equipped with an 8-bit parallel interface.
Specifications and pin assignments
The built-in parallel interface has the following characteristics:
Data format:
8-bit parallel
Synchronization:
STROBE pulse
Handshake timing:
BUSY and ACKNLG signals
Signal level:
TTL compatible
Connectors 36-pin 57-30360 Amphenol connector or
equivalent
Appendix A-9