Epson EMP-70 Projector User Manual


 
58
6.1 Possible Failures
If you think your projector may have failed, first check the indicators on the
unit.
Your projector includes an "operation display indicator" and a "problem/alarm
display indicator" which provide information on projector status.
Operation Display Indicator
Indicator
Status
Cause Remedy or Status
See
Page
Steady
orange
Standby
status
(Not abnormal)
Press the Power button to begin projection.
28
Flashing
orange
Cool-down
in progress
(Not abnormal)
Please wait.
Cool-down* time takes about 2 minutes. (see page
74).
35
You cannot operate the Power button during cool-
down. Press the button again after cool-down ends.
Steady
green
Projection
in progress
(Not abnormal)
29
Flashing
green
Warm-up in
progress
(Not abnormal)
Please wait.
Warm-up time is approximately 30 seconds.
After warm-up is complete, the flashing green
indicator changes to steady green.
29
Not lit No power If the lamp has been replaced, check that the lamp
and lamp cover are attached securely.
68
Check the power cord connections. 28
Check power at the outlet. 28
Operation Display Indicator
Problem/Alarm Display Indicator