1.9 Electrical Characteristics
1) Supply voltage: +24 VDC ± 7%
2) Current consumption (at 24V, room temperature):
High speed mode:
Mean: Approximately 1.8 A
(Character font A α-N, capital letters, 36-character rolling pattern,
42 columns printing)
Peak: Approximately 7.7 A
Low power consumption mode:
Mean: Approximately 1.2 A
(Character font A α-N, capital letters, 36-character rolling pattern,
42 columns printing)
Peak: Approximately 6.6 A
Standby:
Mean: Approximately 0.2 A
NOTE: Maximum 1 A for drawer kick-out driving.
1.10 EMI and Safety Standards Applied
EMC is measured using SEIKO EPSON’s AC adapter
1) Europe CE marking:
Directive: 89/336/EEC
EN55022 Class B
EN55024
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Safety Standard: EN60950
2) North America EMI: FCC/ICES-003 Class A
Safety standards: UL1950/CSA C22.2 No.950
3) Japan EMC: VCCI Class A
4) Oceania EMC: AS/NZS 3548
5) Taiwan EMI: Class B
Conditions of Acceptability
1) This component has been judged on the basis of the required spacing in the Standard for
Information Technology equipment, Including Electrical Business Equipment, UL 1950 and CSA
C22.2 No. 950, Sub-clause 2.9, which would cover the component itself if submitted for Listing.
2) This unit is intended to be supplied by a SELV circuit only.
3) The terminals and connectors have not been evaluated for field wiring.