Epson T88III Printer User Manual


 
Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
B
App.21 App.20
TM-T88III series
Specification
(STANDARD)
APPENDIX K: COMPARISON TABLE BETWEEN TM-T88I
II
II
II
II
II
I
AND TM-T88II
TM-T88
III TM-T88II
1. Print speed
High speed mode
Approximately 150 mm/s maximum Approximately 120 mm/s maximum
2. Availability of a 58-mm
paper width model
None Yes
3. Current consumption
High speed mode
Mean: Approximately 1.8 A Mean: Approximately 1.7 A
4. Interface Baud rate of
serial communication
4800, 9600, 19200, 38400
(2400 is canceled, and 38400 is
added.)
38400 bps is available when both
DIP SW1-7 and 1-8 is On.
2400, 4800, 9600, 19200
5. Condition to release the
receive buffer BUSY
state
Sets with the DIP SW2-5
(Refer to
1)
Fixed to the condition as below:
Except the receive buffer full
(BUSY).
The receive buffer full indicates that
the remaining space in the receive
buffer drops 16 bytes and it
remains until the space in the
receive buffer increases 26 bytes.
6. External power supply
device
Models with the power supply
included as standard or without the
power supply are available.
Packaged power supply: PS-180 ,
PS-175 (only for North America)
PS-170 (option)
7. Multilingual support
Japanese model
Simplified Chinese model
Traditional Chinese model
Thai model
Korean model
Depending on the model type one
of these character is supported.
Japanese model
Simplified Chinese model
Traditional Chinese model
Thai model
Korean model
Depending on the model type one
of these character is supported.
*1 Definition of “receive buffer full”
When the receive buffer capacity is specified to 4 KB (DIP SW1-2 is Off):
If the DIP SW2-5 is off, when the remaining space in the receive buffer drops to 128 bytes,
the printer status becomes “buffer full” and it remains “buffer full” until the space in the
receive buffer increases to 256 bytes.
If the DIP SW2-5 is on, when the remaining space in the receive buffer drops to 128 bytes,
the printer status becomes “buffer full” and it remains “buffer full” until the space in the
receive buffer increases to 138 bytes.
When the receive buffer capacity is specified to 45 bytes (DIP SW1-2 is On):
Regardless of the DIP SW2-5 setting, when the remaining space in the receive buffer drops
to 16 bytes, the printer status becomes “buffer full” and it remains “buffer full” until the space
in the receive buffer increases to 26 bytes.
The printer ignores the data received when the remaining space in the receive buffer
is 0 bytes.
END