4.1 OVERVIEW
This section describes adjustments required when the printer is disassembled and assembled for repair.
After removing an ink cartridge, always install a new cartridge immediately.
During adjustments and testing, use cartridges designed exclusively for service :
Monochrome:1023206
CMY (Color):1029341
Table 4-1. Required Adjustments
Service Performed Adjustment Needed
After replacing the M-4C11 printer mechanism. Bi-D Alignment Adjustment (see 4.1.1)
After replacing the C199 MAIN board.
1. EEPROM Reset (see 4.1.5)
2. Bi-D Alignment Adjustment (see 4.1.1)
When vertical lines are not aligned.
When a white line appears after the printer
performs a single print pass.
1. Bi-D Alignment Adjustment (see 4.1.1)
2. Head Angle Adjustment (see 4.1.2)
After replacing or disassembling the carriage
unit.
Platen Gap Adjustment (see 4.1.4)
When the printer indicates a Maintenance
Error.
Maintenance Error Clear (see 4.1.5.4)
After replacing the waste ink pad. Maintenance Error Clear (see 4.1.5.4)
CAUTION
EPSON Stylus COLOR 200 / EPSON Stylus 200 Adjustments
Rev. A 4-1