Extron • System 4
xi
Switcher Series • User’s Manual
Chapter 4 • Connecting Multiple Switchers
System 8/10 PLUS Switch Settings
From the front access panel on the System 8/10 PLUS, do the following:
1. On DIP switch block SW15, set switches #6 and #8 ON.
2. Set rotary switch RS4 to the “0” position.
On the rear panel of the System 8/10 PLUS, do the following:
3. Set the Norm/VLB switch on the back of the 8/10 PLUS set to “Norm”.
4. Set the Address switches for “master”. (If looping two 8/10 PLUS systems to
the System 4xi, the second one must be set as a “slave”.)
5. Set the Video/RGBS switches to match the type of video to be used by each
input and do the configuration setup.
Go to page 4-7 to configure the master/
slave as a system.
_______ Refer to the System 8/10
PLUS User’s Manual for
other switch settings.
Figure 4-6. System 8/10 Plus Setup Switches
4-6
Figure 4-5. System 8/10 Plus Front Access Panel Switches