Extron electronic DVS 510 SA Switch User Manual


 
DVS 510 Series • Remote Configuration and Control 77
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Event Control
View event buffer memory
27
E X10$,X10%,X10^,X10& E }
X12) ]
Write event buffer memory
24,27
E X10$,X10%,X10^,X10* X10& E }
Evt X10$,X10%,X10^,X10* ]
NOTE: The response to the Write Event command is padded with leading zeros for X10$ and X10^.
X10$ = 5 digits; X10^ = 10 digits.
Write string to event buffer
memory
24,27
E string * X10$,X10%,X10^ FE }
Evt X10$,X10%,X10^,string ]
NOTES: F must be capitalized to read and write strings to event buffer memory.
The response to the Write String command is padded with leading zeros for X10$ and X10^.
X10$ = 5 digits; X10^ = 10 digits.
The Write String command expects a string preceded by E. Strings returned by the device (read or write
response) are binary (non-escaped) data.
View string from event buffer
memory
27
E X10$,X10%,X10^,X11) FE }
String
Start events
24,27
E 1AE } Ego ]
Stop events
24,27
E 0AE } Est ]
Query the number of events
running
E AE } nnnnn ]
In Verbose Mode:
Enm nnnnn ]
Response is a 5-digit number.
Telnet text responses:
event0 starting loc,
length ]
event1 starting loc,
length ]