Setting up FortiBridge units Completing the basic FortiBridge configuration
FortiBridge Version 3.0 Administration Guide
09-30000-0163-20061109 29
Allowing management access to the EXT 1 interface
By default no management access is configured for the EXT 1 interface. Use the
following procedure to add management access to this interface if required.
To allow management access to the EXT 1 interface
1 Log in to the CLI.
2 Allow Telnet and ping management access to the EXT 1 interface. Enter:
config system interface external
set allowaccess telnet ping
end
Changing the system time and date
Use the following procedure to change the system time and date.
To change the system time and date
1 Log in to the CLI.
2 Change the system time. Enter:
execute time <hh:mm:ss>
For example:
execute time 12:24:34
3 Change the system date. Enter:
execute date <mm/dd/yyyy>
For example:
execute date 04/26/2005
4 Change the FortiBridge system time zone. Enter:
config system global
set timezone <timezone_integer>
end
Enter the number corresponding to your time zone. Type ? to list time zones and
their numbers. Choose the time zone from the list and enter the correct number.
For example, to set the time zone to Central time (time zone number 8), enter:
config system global
set timezone 8
end
For information about configuring other global settings, see “system global” on
page 66.
Adding administrator accounts
The factory default FortiBridge configuration includes the admin administrator
account. Use this procedure to add more administrator accounts.
To add administrator accounts
1 Log in to the CLI.
2 Add an administrator. Enter: