Fujitsu 4Gbit/s FC I/O Modules Network Router User Manual


 
5 4Gbit/s FC I/O Module Details Setting 65
E
7 Set a value in "New Value", check "Permanent", and click [Change].
When the settings vary for each adapter, remove the check on the "Global".
The setting value is calculated as follows:
For ETERNUS3000 model 50/GR710/GR720/GR730/GR740/GR820/GR840
For cluster (MSCS/SynfinityCluster): "8"
For other than cluster (MSCS/SynfinityCluster)
When one HBA is connected to one FC-CA (FC port): "16"
When two HBAs are connected to one FC-CA (FC port): "8"
For ETERNUS3000 model 80/100/200/300/400/500/600/700 and
ETERNUS4000 model 80/100
Setting value (rounding down decimals) = 40/ (number of 4Gbit/s FC I/O Module connected
to one CA port)
When the calculated value is 8 or less, specify "8".
For ETERNUS6000 model 400/500/600/700/800/900/1000/1100
Specify "40".
For ETERNUS4000 model 300/500 and ETERNUS8000
Specify "255".
When the setting value for all the installed adapters is "8":
When the setting value for only the adapter under setting is "40":