6 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • November 2007
Hardware Installation and Service Issues
This section describes hardware specific issues and workarounds.
Specific Issues and Workarounds
TABLE 1 lists known hardware issues and possible workarounds.
TABLE 1 Hardware Issues and Workarounds
CR ID Description Workaround
6433420 The domain console might display a Mailbox
timeout or IOCB interrupt timeout error during
boot.
Issue a reset -all command from the
OpenBoot PROM (OK) prompt and reboot.
6488846 During boot, the domain console might display
a checksum error for the SG(X)PCI2SCSIU320-
Z SCSI controller I/O card.
Check for the availability of the latest
controller card firmware.
6498780 On the SPARC Enterprise M4000/M5000
servers, the OpenBoot PROM (OBP) might not
detect the on-board disk (HDD) boot device.
Performing a boot disk results in a console
message:
Can’t locate boot device
The PCI or PCI-X plug-in adapter card might
not be seated correctly. Reseat the card in slot 0
of the IOU.