Fujitsu M4000/M5000 Server User Manual


 
SPARC Enterprise M4000/M5000 Servers Product Notes 11
Electrical Specifications
The following changes belong in the SPARC Enterprise M4000/M5000 Servers
Service Manual.
SPARC Enterprise
M4000/M5000 Servers
Service Manual
9-1
15-1
CHAPTER 9, "XSCF Unit Replacement"
CHAPTER 15, "Operator Panel Replacement"
The following important message will be added.
Note – If you replace the XSCF unit and the operator
panel simultaneously, system will not operate normally.
Execute the showhardconf command or the
showstatus command to confirm that the component
replaced earlier is operating normally, before replacing
the subsequent FRU.
SPARC Enterprise
M4000/M5000 Servers
Service Manual
11-7 11.2, "DIMM Replacement"
See “DIMM Replacement” on page 14 for the changes.
SPARC Enterprise
M4000/M5000 Servers
Service Manual
C-7 TABLE C-5 "Power Supply Feature"
See “Electrical Specifications” on page 11 for the changes.
TABLE 3 Power Supply Features
SPARC Enterprise M4000 SPARC Enterprise M5000
Power draw (maximum)
2016W 3738W
Volt Ampere
2058 VA 3815 VA
Heat
6879 BTUs/hr (7258 kJ/hr) 12754 BTUs/hr (13457 kJ/hr)
TABLE 2 Documentation Updates (Continued)
Title Page Number Update