SPARC Enterprise M4000/M5000 Servers Product Notes 21
6496337 The "cpumem-diagnosis" module may fail to
load after uncorrectable error(UE) panic.
Systems will function correctly but events
normally automatically diagnosed by FMA
using this module will require manual
diagnosis.
Example:
SUNW-MSG-ID: FMD-8000-2K, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Thu Feb 15 15:46:57 JST
2007
PLATFORM: SUNW,SPARC-Enterprise,
CSN: BE80601007, HOSTNAME: col2-ff-
em7-d0
If problem occurred, implement the following
workaround:
1. Remove the following file.
# rm /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
2. Restart fmd service.
# svcadm restart fmd
To avoid this problem in advance,
add "rm -f /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis"in
/lib/svc/method/svc-dumpadm file as below.
#
# We haven't run savecore on a
dump device yet
#
savedev=none
rm -f /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
#
This bug has been fixed in Solaris 10 8/07.
6498283 Using the DR deleteboard(8) command
while psradm operations are running on a
domain might cause a system panic.
There is no workaround. Check for the
availability of a patch for this defect.
This bug has been fixed in Solaris 10 8/07.
6499304 CPU isn't offlined and unexpected message is
displayed on console when many correctable
error(CE) occurs.
Example:
SUNW-MSG-ID: FMD-8000-11, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Fri Feb 2 18:31:07 JST
2007
PLATFORM: SPARC-Enterprise, CSN:
BE80601035, HOSTNAME: FF2-35-0
Check CPU status on XSCF.
This bug has been fixed in Solaris 10 8/07.
TABLE 7 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround