Fujitsu RX900 S1 Server User Manual


 
266 Maintenance Manual RX900 S1
Baseboard
Figure 165: Checking the installation position
Ê Remove the SAS and BBU cable(s) for a convenient access to the mounting
location of the UFM.
Ê Make sure that the metal spacer (A) engages properly in the baseboard.
Figure 166: Installing the UFM board
Ê Place the UFM on the metal spacer (A) and the connector (B) in figure 165
and secure it with the nylon screw.
14.2.4 Completing the task
Ê Perform the following procedures to complete the task:
1. When expansion cards have been removed to access the installation
place: Install the expansion cards, see "Expansion cards and BBU" on
page 105
2. "Installing the rear cover" on page 48
3. "Mounting the server in the rack" on page 49
4. "Bringing the server back to operation" on page 51
5. "Closing the rack door" on page 51
C
A
C
B