Basic procedures
Ê Insert the inner parts of the rails that are mounted on the server into the
protruding middle parts until the rails engage (2).
Ê Release the locking mechanism of both rails (3).
– Left side oft the server: Push upwards
– Right side of the server: Push downwards
Ê Lower the lifter platform and slide the server into the rack (4). Remove the
lifter.
V CAUTION
Do not use the front handles to raise the server as they are not designed
to bear the weight of the unit. The front handles are only to be used for
pushing the server into the rack or pulling it out of the rack.
Sliding the Server into the rack
Ê Slide the server into the rack.
Ê Fasten the server to the rack with the four knurled screws on the front panel
and the cage nuts, see (5) in figure 10.
Ê Route the cables as described in the Technical manual for the rack in
question.