Fujitsu RX900 S1 Server User Manual


 
86 Maintenance Manual RX900 S1
Hard disk and solid state drives
6.2.4 Removing the HDD/SSD module
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait for at least 60 seconds.
I This period is necessary for the RAID controller to recognize that an
HDD/SSD module has been removed and for the hard disk drive to
come to a stop.
Ê Pull the HDD/SSD module out completely.
6.2.5 Completing the task
Perform one of the following procedures to complete the task:
1. "Installing the dummy module" on page 88
2. "Installing the HDD/SSD module" on page 80
6.3 Removing the HDD/SSD module
6.3.1 Required tools
Starting and completing the task:
key for the rack doors (if applicable)
Removing the HDD/SSD module: tool-less
6.3.2 Starting the task
Ê Perform the following procedures:
1. "Opening the rack door" on page 40
Trained personnel