Magnum 3000 Stackable Hubs Installation and User Guide (07/06)
36
www GarrettCom com
..
5.2 Installation, General Information
The Magnum SNMP agent is an option with the Magnum 3000 Stackable Hubs
and Concentrators. The SNMP embedded agent, Model 3000-MB, will be configured
and tested as part of a Magnum 3000 stack or single unit at the factory when specified at
the time of order. In order to satisfy network growth and changing network
requirements, Magnum 3000 Stackable Hubs may also be upgraded in the field with the
addition of a Magnum SNMP agent box such as Model 3000-AGT.
With either of the two agent implementations, the agent's operation and
performance is the same. The selection of the desired version is entirely a function of
user preference. For one Magnum 3000 stack (which may be from one to twenty units,
and may be any combination of 3024 and 3012 units), only one SNMP agent is required,
and only one SNMP agent may be in use at any given time.
5.3 Installing the Embedded Agent Board, "MB"
The embedded agent board, Model 3000-MB, is normally factory installed.
The procedure for installing the Magnum 3000-MB in the field is a moderately
complex process. (To avoid complex field installation and test procedures, it is
recommended that a Magnum 3000-AGT agent box unit be chosen and added to the
existing stack when a field upgrade from non-managed to embedded-agent-managed is
desired).
The following step-by-step procedure should be followed to properly install
the Magnum SNMP embedded agent board.
STOP!!!
Be sure the power cord is unplugged
from the chassis before attempting to remove
and/or replace an RPM card.
Failure to do so may result in damage to the unit
and will void the warranty.