GarrettCom Magnum 3000 Switch User Manual


 
Magnum 3000 Stackable Hubs Installation and User Guide (07/06)
1
www GarrettCom com
..
1.0 Specifications - Magnum 3024, Magnum 3012
Performance
Data Rate: 10 Mbps
RPM Partitioning: Enforced after 32 consecutive collisions
RPM Reconnect: Occurs after 512 bits error-free reception
BPM Auto-Learning Address List: 256 nodes capacity
BPM Filtering and Forwarding Rate: 14,880 pps max.
Maximum Ethernet Segment Lengths
DTE (AUI Drop Cable) - 50 m (164 ft)
10BASE-T (twisted pair) - 100 m (328 ft)
Shielded twisted pair - 150m (492 ft)
10BASE2 ThinNet (BNC) - 185 m (607 ft)
10BASE5 ThickNet - 500 m (1,640 ft)
FOIRL multi-mode Fiber optic - 1 km (3,281 ft)
10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)
Single-mode Fiber optic - 10 km (32,810 ft)
Network Standards
Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5,
10BASE2, 10BASE-FL & FOIRL, and DTE
Operating Environment
Ambient Temperature: 25ºF to 120ºF (-5ºC to 50ºC)
Storage Temperature: -40ºF to 185ºF (-40ºC to 85ºC)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 Ft. (-60 to 4000 m)
Conformal coating option: Request quote
Port Connector Types
RJ-45: Shielded, 8-Pin Female (Note: Shielded 10BASE-T
connectors accept either unshielded or shielded wiring
plugs for standard twisted pair media wiring.)
Fiber Optic: ST (Twist-Lock Connector, for single and multi-mode)
Fiber Optic: SC (Snap-in Connector, for multi-mode fiber cables only)
ThinNet: BNC
AUI: D-Sub 15-Pin Female (with slide lock)
DTE: D-Sub 15-Pin Male (with lock posts)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed, rear of chassis
Input Voltage: 100 - 240 vac (auto-ranging)
Input Frequency: 47 - 63 Hz (auto-ranging)
Power Consumption: Model 3024: 18 watts typical; 30 watts max,
Model 3012: 10 watts typical; 20 watts max,
3000-AGT: 9 watts typical; 20 watts max,