HP (Hewlett-Packard) 445942-001 Switch User Manual


 
Statistics Commands
90
Table 64 OSPF global statistics
Statistic Description
n1way
The sum total number of Hello packets received from neighbors, in which this router is not
mentioned across all OSPF interfaces and areas.
rst_ad
The sum total number of times the Neighbor adjacency has been reset across all OPSF
areas and interfaces.
down
The total number of Neighboring routers down (that is, in the initial state of a neighbor
conversation) across all OSPF areas and interfaces.
Intf Change Stats:
up
The sum total number of interfaces up in all OSPF areas.
down
The sum total number of interfaces down in all OSPF areas.
loop
The sum total of interfaces no longer connected to the attached network across all OSPF
areas and interfaces.
unloop
The sum total number of interfaces, connected to the attached network in all OSPF areas.
wait timer
The sum total number of times the Wait Timer has been fired, indicating the end of the
waiting period that is required before electing a (Backup) Designated Router across all
OSPF areas and interfaces.
backup
The sum total number of Backup Designated Routers on the attached network for all OSPF
areas and interfaces.
nbr change
The sum total number of changes in the set of bidirectional neighbors associated with
any interface across all OSPF areas.
Timers Kickoff:
hello
The sum total number of times the Hello timer has been fired (which triggers the send of
a Hello packet) across all OPSF areas and interfaces.
retransmit
The sum total number of times the Retransmit timer has been fired across all OPSF areas
and interfaces.
lsa lock
The sum total number of times the Link State Advertisement (LSA) lock timer has been fired
across all OSPF areas and interfaces.
lsa ack
The sum total number of times the LSA Ack timer has been fired across all OSPF areas
and interfaces.
dbage
The total number of times the data base age (Dbage) has been fired.
summary
The total number of times the Summary timer has been fired.
ase export
The total number of times the Autonomous System Export (ASE) timer has been fired.