HP (Hewlett-Packard) 654080-S01 Server User Manual


 
Specifications 113
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Nonoperating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Server specifications
Specification Value
Dimensions
Rack model
Height
17.48 cm (6.88 in)
Depth
69.93 cm (27.53 in)
Width
48.34 cm (19.03 in)
Tower model
Height
47.04 cm (18.52 in)
Depth
73.96 cm (29.12 in)
Width
24.77 cm (9.75 in)
Weight
Weight (when lightly loaded)
Rack
25.00 kg (55.12 lbs)
Tower
30.00 kg (66.14 lbs)
Weight (maximum)
46.75 kg (103.06 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 1200 W Power Supply