HP (Hewlett-Packard) 654080-S01 Server User Manual


 
Removal and replacement procedures 55
3.
Install the heatsink. and close the heatsink retaining latches.
4. Install the air baffle.
5. If removed, install the BBWC battery pack or the FBWC capacitor pack.
6. Install fan 5.
7. Install the access panel.
8. Do one of the following:
o Install and lock the bezel.
o Slide the server back into the rack.
9. Power up the server.
Processor
The server supports single- and dual-processor operation. With two processors installed, the server supports
boot functions through the processor installed in processor socket 1. However, if processor 1 fails, the system
attempts to boot from processor 2 and provides a processor failure message.
The server uses embedded PPMs to provide power to each processor.
CAUTION: To avoid damage to the processor and system board, only authorized personnel
should attempt to replace or install the processor in this server.
CAUTION: To avoid damage to the processor:
Handle the processor only by the edges.
Do not touch the bottom of the processor, especially the contact area.
IMPORTANT:
Processor socket 1 must always be populated. If processor socket 1 is empty, the
server halts during POST.
To remove the component:
1. Update the system ROM.