HP (Hewlett-Packard) 776978-S01 Server User Manual


 
Removal and replacement procedures 39
Standard hard drive cage
The procedure is the same for both the standard six-bay LFF hard drive cage and the standard eight-bay SFF
hard drive cage.
To remove the component:
1. Power down the server (on page 27).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Front bezel" on page 30).
o Extend the server from the rack (on page 28).
3. Place the tower server on its side.
4. Remove the access panel ("Access panel" on page 31).
5. Disconnect all cables from the rear of the hard drive cage.
6. Remove the hard drive cage.
7. Remove all hard drives ("SAS/SATA hard drive" on page 38).
To replace the component, reverse the removal procedure.
Optional eight-bay SFF hard drive cage
To remove the component:
1. Power down the server (on page 27).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Front bezel" on page 30).
o Extend the server from the rack (on page 28).
3. Place the tower server on its side.
4. Remove the access panel ("Access panel" on page 31).
5. Remove all hard drives ("SAS/SATA hard drive" on page 38).
6. Disconnect all cables from the rear of the hard drive cage.