HP (Hewlett-Packard) 776978-S01 Server User Manual


 
Removal and replacement procedures 56
o
Full-height
To replace the component, reverse the removal procedure.
IMPORTANT: Be sure to connect the right-angle end of the SATA data cable to the system board.
Connecting it to the SATA drive may interfere with other installed media bay devices.
IMPORTANT: If both SATA and PATA optical devices are installed simultaneously, only one can
boot at a time. Boot priority will go to SATA if media is inserted into the SATA optical drive. Boot
priority for PATA is not configurable. To boot PATA, remove the media from the SATA optical
device, or remove the SATA optical device.
DIMM
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM identification (on page 87)."
1. Power down the server (on page 27).
2. Do one of the following:
o Unlock and remove the bezel ("Front bezel" on page 30).
o Extend the server from the rack (on page 28).
3. Remove the access panel ("Access panel" on page 31).
4. Remove the large redundant fan air baffle, if installed ("Large redundant fan air baffle" on page 33).
5. Remove the DIMM baffles ("DIMM baffle" on page 34).
6. Remove a fan, if necessary ("Fan" on page 35).
7. Open the DIMM slot latches.