HP (Hewlett-Packard) C30D Printer User Manual


 
2-6 TAG Cross- Reference Tables
Table 2-5. IGS Firmware Error Codes
Code
IGS Firmware Error Code Meaning
These error codes signal a problem with the IGS controller
firmware. No TAGs address these problems; report them to the
printer’s manufacturer.
Go to TAG
301 Status received after VSS asserted No TAG
302 Status tag asserted after VSS not asserted No TAG
303 VSC command not asserted after command tag asserted No TAG
304 VSC command asserted after data was sent No TAG
305 VSC command not asserted for next data byte No TAG
306 Status tag asserted while data was being sent No TAG
307 Parity error on command line No TAG
Table 2-6. PCL Failure Error Codes
Code PCL Failure Error Code Meaning Go to TAG
380 PCL board failure - command retries 201
381 PCL board failure - command rejected 201
382 PCL board failure - bad command received 201
383 PCL board failure - unexpected byte received 201
384 PCL board failure - no status received 201
385 PCL board failure - bad status information block count 201
386 PCL board failure - bad status information block offset 201
387 PCL board failure - parity error 201
389 Floppy disk retry 130
Table 2-7. IGS Software Error Codes
Code
IGS Software Error Code Meaning
These error codes signal a problem with the IGS controller
software. No TAGs address these problems; to determine
whether the faulty software is the customer’s or the
manufacturer’s, contact the printer’s manufacturer.
Go to TAG
397 IGS software trap No TAG
398 IGS software trap No TAG
399 IGS software trap No TAG