Arr ay s
See Figure 18. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or more logical units (L1) called arrays. When this is
done, the read/write heads of all the c onstituent physical drives are a ctive simultaneously, dramatically
reducing the ov
erall time required for data transfer.
NOTE:
Depending on the storage server model, array conguration may not be possible or necessary.
P1 P3P2
L1
gl0042
Figure 18 Conguring arrays from physical drives
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of data
stripes over all the ha rd drives in an array, as shown in Figure 19.
S1
S2
S3
S4
B1
B4
B7
B2
B5
B8
B11B10 B12
B6
B3
B9
gl0043
Figure 19 RAID 0 (da ta striping) (S1- S4) of data blocks (B1-B12)
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the data blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array, the extra capacity is
wastedbecauseitcannotbeusedbythearray.
Fault tolerance
Drive failure, although rare, is potentially catastrophic. For example, using simple striping as shown in
Figure 19, failure of any hard drive leads to failure of all logical d rives in the same array, and hence to
data loss.
To protect against data loss from ha rd drive failure, storage servers should be congured with fault
tolerance. HP recommends adhering to RAID 5 congurations.