HP (Hewlett-Packard) LC 2000 Server User Manual


 
Chapter 13 Alternative Rack Mounting
155
The mounting tabs in the slides should be in position to fit into the
openings in chassis. See Figures 13-6 and 13-7.
8. Lower the NetServer onto the slide members.
The NetServer’s handles will temporarily support the NetServer on the
slides.
9. Adjust the NetServer’s position on the slides to line up the 6 mounting
holes on the side (3 each) of the chassis with the screw holes in the slide
members.
10. Insert the flathead screws into the slides’ holes at the rear and the panheads
screws in the other four places to secure the chassis to the slides.
11. Use a Torx T-15 driver to remove the screws holding the handles to the
NetServer. See Figure 13-8.
12. Take the handles off the NetServer and store the handles and screws in a
convenient place.
The handles can be re-attached whenever you remove the NetServer from
the rack. If moving the NetServer elsewhere, always package it with the
handles attached.
Figure 13-8. Removing the Mounting Handles