HP (Hewlett-Packard) LC 2000 Server User Manual


 
Chapter 8 Rack-Mounting the HP NetServer
80
NOTE If you want to put your NetServer into a third-party rack not
mentioned in the guide, you may be able to find relevant
documentation on HP’s web site at the following URL:
http://www.hp.com/netserver/support
The HP NetServer rack mount kit requires five EIA units of space in the rack.
Before mounting the NetServer, plan the NetServer’s location in the rack relative
to other rack components. Proper placement is vital both for safety and operating
efficiency. For more details, see the HP Rack Installation Road Map and the HP
NetServer LC 2000r Rack Cabling Reference Guide.
NOTE If the HP NetServer is completely configured by the vendor
before delivery to the customer, then mounting the HP
NetServer in the rack may be the final step in the installation
procedure. If the vendor configures the HP NetServer at the
customer’s site, installation of the network operating system
and other software may occur after the HP NetServer is
mounted in the rack.
WARNING The HP NetServer weighs 80 lbs. (36 kg) fully loaded. To
prevent an accident, use two people when placing the
NetServer into the rack.
CAUTION If other rack components are to be mounted in the rack below
the HP NetServer, install those components before starting to
mount the NetServer.
Tools Required
To assemble the rack mount kit and install the HP NetServer on it, you need these
tools.
T-15 and T-25 Torx Drivers
Number 2 Phillips screwdriver
Marking pen