HP (Hewlett-Packard) LXR 8500 Server User Manual


 
Chapter 2 PCI Hot Plug Utility for Novell NetWare
43
Amber
LED
Green
LED
Slot Status Indicates This Status
Active
Power to the slot is on, and the slot is
operating normally. Do not remove the board
from the slot.
On Off Powered Off
(wrong board
or no board)
Power to the slot is off, but the Amber LED is
on, due to a failure in the Hot Replacement
process. Typically this is the result of
installing the wrong board, because the
replacement board must be the same type as
the original PCI board. This also occurs if the
board is removed, emptying the slot, and
power is turned on. You can safely remove
the board from this slot.
Off Off Powered Off Power to the slot is off. You can safely
remove the board from this slot.
7. If you replaced a Disk Drive Controller board, causing it to dismount its
disk drives, re-mount the disk drives to ensure the Disk Drive Controller
board is working correctly.
Remounting the drives must be done outside the Novell Configuration
Manager Console (NCMCON) user interface.
8. If you are assured of the PCI board's operation, including its driver,
continue with the next step.
9. If all desired Hot Plug boards have been replaced, replace the PCI access
panel (refer to your Installation Guide).
CAUTION To prevent damage to cables, use caution when sliding the
chassis into the rack, if the Cable Management Arm is not
used.
10. Slide the chassis slowly back into the rack (refer to your Installation
Guide).
11. Return the HP NetServer to normal operation (refer to your Installation
Guide).