HP (Hewlett-Packard) ML330 G6 Server User Manual


 
Specifications 122
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
9.4 A at 100 VAC
4.7 A at 200 VAC
Rated input power
857 W at 100V AC input
852 W at 200V AC input
BTUs per hour
2924 at 100V AC input
2907 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10.0 A at 100 VAC
5.0 A at 200 VAC
Rated input power
626 W at 100V AC input
676 W at 200V AC input
BTUs per hour
2306 at 100V AC input
2306 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Maximum peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input