HP (Hewlett-Packard) StudioJet Printer User Manual


 
54
Ioline FlexJet E User Guide
A marker plot doesn’t start at the correct point on the paper
Cause:
The origin is not set.
Solution:
Position the pen where the plot
should start. Press the Set Origin key.
The printer does not complete the marker.
Cause:
1. Outdated software.
2. The frame/panel size is mis-
matched between the printer
and the design software.
Solution:
1. Visit the Ioline Web site to
download upgrades. Or, contact
Ioline Customer Service.
2. Check the panel size in the
software. It should be equal to or
lower than the printer panel size.
Send plot les from FlexPlot.
When a marker plot le is sent, nothing happens.
Cause:
A communication problem has oc-
curred or the printer is in STOP
(red light) mode.
Solution:
Make certain the communication port
is connected and congured properly.
Position the marker on the carriage
where the plot should start and press
the Set Origin key to put the printer
in START (green light) mode.
No power when printer is turned on; keypad lights stay dark.
Cause:
1. The power cord is damaged or
disconnected.
2. The printer is damaged and
needs professional service.
Solution:
1. Check the power connection.
2. Contact an Ioline distributor or
Ioline Customer Service.
Poor line quality.
Cause:
1. Ink cartridge is improperly
installed.
2. Frame Gap setting is incorrect.
3. Carriage electronics or cables
are damaged.
4. Ink cartridge is empty.
Solution:
1. Remove and reinstall ink car-
tridge.
2. Use the Control Center to
adjust frame gap as shown in
the Routine Maintenance
chapter.
3. Contact Ioline customer service.
4. Install a new ink cartridge.
Common Issues