Hitachi SJ-PB(T) Power Supply User Manual


 
APPENDIX PARAMETER CROSS-REFERENCE LIST
24
Code No. Size Range Magn. Contents L300P
Read/
Write
H033 82 4
0 655.35A
*100 1st No load current Io of motor (Auto) No R/WOS
H233 83 4
0 655.35A
*100 2nd No load current Io of motor (Auto) No R/WOS
H034 84 4
0.001
9999.000kgm2
*100 1st Inertia J of motor (Auto) No R/WOS
H234 85 4
0.001
9999.000kgm2
*100 2nd Inertia J of motor (Auto) No R/WOS
A043 86 2
0 50.0%
*10 1st Break point of manual torque boost R/W
A243 87 2
0 50.0%
*10 2nd Break point of manual torque boost R/W
A343 88 2
0 50.0%
*10 3rd Break point of manual torque boost No R/W
A052 89 2
0 60.00Hz
*100 Frequency of DC braking start R/WOS
A055 90 2
0 60.0s
*10 Time of DC braking working R/WOS
A058 91 2
0 60.0s
*10
Time of DC braking working
for beginning of inverter running
R/WOS
A064 92 2
0 10.00Hz
*100 Width of jumping frequency 1 R/WOS
A066 93 2
0 10.00Hz
*100 Width of jumping frequency 2 R/WOS
A068 94 2
0 10.00Hz
*100 Width of jumping frequency 3 R/WOS
A070 95 2
0 60.0s
*10 Time of stopping to accelerate R/WOS
A073 96 2
0 3600.0s
*10 Integrate (I) gain of PID control R/W
A074 97 2
0 100.00
*100 Differential (D) gain of PID control R/W
A075 98 2
0.01 99.99%
*100 Scale of PID control R/WOS
A086 99 2
0 100.0
*10 Response time of Energy saving function R/W
b003 101 2
0.3 100.0s
*10 Waiting time of retry R/WOS
b012 102 2
20.0 120.0
*10 Level of 1st Electronic thermal protection R/WOS
b212 103 2
20.0 120.0
*10 Level of 2nd Electronic thermal protection R/WOS
b312 104 2
20.0 120.0
*10 Level of 3rd Electronic thermal protection No R/WOS
b015 105 2
0 400Hz
*1 Free electronic thermal frequency 1 R/WOS
b016 106 2
0 1000.0A
*10 Free electronic thermal current 1 R/WOS
b017 107 2
0 400Hz
*1 Free electronic thermal frequency 2 R/WOS
b018 108 2
0 1000.0A
*10 Free electronic thermal current 2 R/WOS
b019 109 2
0 400Hz
*1 Free electronic thermal frequency 3 R/WOS
b020 110 2
0 1000.0A
*10 Free electronic thermal current 3 R/WOS
b100 111 2
0 400Hz
*1 Free V/F control frequency 1 R/WOS
b101 112 2
0.0 800.0V
*10 Free V/F control voltage 1 R/WOS
b102 113 2
0 400Hz
*1 Free V/F control frequency 2 R/WOS
b103 114 2
0.0 800.0V
*10 Free V/F control voltage 2 R/WOS
b104 115 2
0 400Hz
*1 Free V/F control frequency 3 R/WOS
b105 116 2
0.0 800.0V
*10 Free V/F control voltage 3 R/WOS
b106 117 2
0 400Hz
*1 Free V/F control frequency 4 R/WOS
b107 118 2
0.0 800.0V
*10 Free V/F control voltage 4 R/WOS
b108 119 2
0 400Hz
*1 Free V/F control frequency 5 R/WOS
b109 120 2
0.0 800.0V
*10 Free V/F control voltage 5 R/WOS
b110 121 2
0 400Hz
*1 Free V/F control frequency 6 R/WOS
b111 122 2
0.0 800.0V
*10 Free V/F control voltage 6 R/WOS
b112 123 2
0 400Hz
*1 Free V/F control frequency 7 R/WOS
b113 124 2
0.0 800.0V
*10 Free V/F control voltage 7 R/WOS
b022 125 2
50.0 200.0
*10 Level of Overload restriction 1
50.0
150.0
R/WOS