Hitachi SJ-PB(T) Power Supply User Manual


 
APPENDIX PARAMETER CROSS-REFERENCE LIST
26
Code No. Size Range Magn. Contents L300P
Read/
Write
C088 164 1
0.0 20.0mA
*10 Adjustment of Offset of AMI output R/W
C091 166 1 00,01 code Selection of Debug mode method R/W
C041 168 2
0 200.0(%)
*10 Level1 of overload restriction warning R/WOS
C111 169 2
0 200.0(%)
*10 Level2 of overload restriction warning No R/WOS
C044 170 2
0 100.0%
*10
Level over acceptable deviation of
PID control
R/WOS
C063 171 2
0 100.00Hz
*100 Level f detecting Zero speed No R/WOS
C061 173 2
0 100%
*1
Warning Level of
electronic thermal protection
R/WOS
C078 174 2
0 1000ms
*1 Waiting time of communication start R/WOS
P011 176 2
128 65000pls
*1 Pulse number of the encoder No R/WOS
P014 177 2
0 4095
*1 Stop position at Orientation mode No R/WOS
P015 178 2
0 120.00Hz
*100 Speed at Orientation mode No R/WOS
P017 179 2
0 10000pls
*1
Defining Area of completion of
Orientation mode
No R/WOS
P018 180 2
0 9.99s
*100
Delay time of completion
Orientation mode
No R/WOS
P020 181 2
0 9999
*1 The numerator of electric gear No R/WOS
P021 182 2
0 9999
*1 The denominator of electric gear No R/WOS
P022 183 2
0 655.35
*100 Feed forward gain of position control No R/WOS
P023 184 2
0 100.00
*100 Loop gain of position control No R/WOS
P026 185 2
0 150.0
*10 Level of detecting over speed No R/WOS
P027 186 2
0 120.00Hz
*100 Value of detecting over deviation No R/WOS
F004 188 1 00,01 code
Selection of running direction
for DIG-OPE
R/WOS
A001 189 1
00 05
code Selection of frequency command destination R/WOS
A002 190 1
01 05
code Selection of running command destination R/WOS
A005 191 1 00,01 code Selection of AT function R/WOS
A006 192 1
00 02
code Selection of O2 terminal function R/WOS
A013 193 1
0 100%
*1 Starting rate of O terminal R/WOS
A014 194 1
0 100%
*1 End rate of O terminal R/WOS
A015 195 1 00,01 code Selection of starting function of O terminal R/WOS
A016 196 1
1 30times
*1 Analog Sampling R/WOS
A113 197 1
-100 100%
*1 Starting rate of O2 terminal R/WOS
A114 198 1
-100 100%
*1 End rate of O2 terminal R/WOS
A103 199 1
0 100%
*1 Starting rate of OI terminal R/WOS
A104 200 1
0 100%
*1 End rate of OI terminal R/WOS
A105 201 1 00,01 code Selection of starting function of OI terminal R/WOS
A019 203 1 00,01 code Selection of Multispeed method R/WOS
A039 204 1
00 05
code Selection of Jogging method R/WOS
A041 205 1 00,01 code Selection of 1st Torque boost Method R/WOS
A241 206 1 00,01 code Selection of 2nd Torque boost Method R/WOS
A042 207 1
0 20.0%
*10 Value of 1st Manual torque boost R/W
A242 208 1
0 20.0%
*10 Value of 2nd Manual torque boost R/W
A342 209 1
0 20.0%
*10 Value of 3rd Manual torque boost No R/W
A044 210 1
00 05
code Selection of 1st Control method
00 02
R/WOS
A244 211 1
00 04
code Selection of 2nd Control method
00 02
R/WOS
A344 212 1 00,01 code Selection of 3rd Control method No R/WOS