Hitachi SJ-PB(T) Power Supply User Manual


 
APPENDIX PARAMETER CROSS-REFERENCE LIST
27
Code No. Size Range Magn. Contents L300P
Read/
Write
A045 213 1
20 100%
*1 Gain of output voltage R/W
A051 214 1 00,01 code Selection of DC braking method R/WOS
A053 215 1
0 5.0s
*10 Delay time of DC braking start R/WOS
A054 216 1
0 100
*1 Power of DC braking(end of running) R/WOS
A056 217 1 00,01 code
Selection of edge/level action of
DC braking trigger
R/WOS
A057 218 1
0 100
*1 Power of DC braking(start of running) R/WOS
A059 219 1
0.5 15.0kHz
*10 Carrier frequency of DC braking
0.5 12.0
R/WOS
A071 220 1 00,01 code Selection of PID control presence R/WOS
A072 221 1
0.2 5.0
*10 Proportional(P) gain of PID control R/W
A076 222 1 00,01 code
Selection of feedback destination for
PID control
R/WOS
A081 223 1
00 02
code Selection of AVR function R/WOS
A082 224 1
0 10
code Selection of Motor voltage R/WOS
A085 225 1
00 02
code Selection of operation mode 00,01 R/WOS
A094 226 1 00,01 code Selection of 1st 2-stage accel/decel Method R/WOS
A294 227 1 00,01 code Selection of 2nd 2-stage accel/decel Method R/WOS
A097 228 1
00 03
code Selection of acceleration pattern R/WOS
A098 229 1
00 03
code Selection of deceleration pattern R/WOS
A131 230 1
01 10
code Curve constant of acceleration R/WOS
A132 231 1
01 10
code Curve constant of deceleration R/WOS
b001 233 1
00 03
code Selection of retry method R/WOS
b002 234 1
0.3 1.0s
*10
Acceptable time for
Instantaneous power failure
R/WOS
b004 235 1
00 02
code
Selection of method(action) at instantaneous
power andunder voltage
R/WOS
b005 236 1 00,01 code
Retry number of instantaneous power
and under voltage
R/WOS
b006 237 1 00,01 code Selection of fail phase function R/WOS
b013 238 1
00 02
code
Selection of characteristic of
1st electronic thermal protection
R/WOS
b213 239 1
00 02
code
Selection of characteristic of
2nd electronic thermal protection
R/WOS
b313 240 1
00 02
code
Selection of characteristic of
3rd electronic thermal protection
No R/WOS
b021 242 1
00 03
code Selection of method of overload restriction1 R/WOS
b024 243 1
00 03
code Selection of method of overload restriction2 R/WOS
b031 244 1
00 03,10
code Selection of method of Software lock R/WOS
b037 245 1
00 02
code Selection of Display R/WOS
b040 247 1
00 04
code Selection of method of Torque limiter No R/WOS
b041 248 1
0 200%
*1
Level of torque limiter in forward
and drive (1st quadrant)
No R/WOS
b042 249 1
0 200%
*1
Level of torque limiter in reverse
and regenerative (2nd quadrant)
No R/WOS
b043 250 1
0 200%
*1
Level of torque limiter in reverse
and drive (3rd quadrant)
No R/WOS
b044 251 1
0 200%
*1
Level of torque limiter in forward
and regenerative (4th quadrant)
No R/WOS