Hitachi SJ-PB(T) Power Supply User Manual


 
APPENDIX PARAMETER CROSS-REFERENCE LIST
31
Code No. Size Range Magn. Contents L300P
Read/
Write
d084 376 2
0 1000.0V
*10 PN voltage (DC voltage) of Trip4 RO
d084 377 4
0
4294836225s
*1
Accumulated time during running
of Trip4
RO
d084 378 4
0
4294836225s
*1
Accumulated time during power ON
of Trip4
RO
d085 379 4
00 H'FF
*1 Factor and Status of Trip5 RO
d085 380 4
0 400.00Hz
*100 Frequency of Trip5 RO
d085 381 2
0 1000.0A
*10 Output current of Trip5 RO
d085 382 2
0 1000.0V
*10 PN voltage (DC voltage) of Trip5 RO
d085 383 4
0
4294836225s
*1
Accumulated time during running
of Trip5
RO
d085 384 4
0
4294836225s
*1
Accumulated time during power ON
of Trip5
RO
d086 385 4
00 H'FF
*1 Factor and Status of Trip6 RO
d086 386 4
0 400.00Hz
*100 Frequency of Trip6 RO
d086 387 2
0 1000.0A
*10 Output current of Trip6 RO
d086 388 2
0 1000.0V
*10 PN voltage (DC voltage) of Trip6 RO
d086 389 4
0
4294836225s
*1
Accumulated time during running
of Trip6
RO
d086 390 4
0
4294836225s
*1
Accumulated time during power ON
of Trip6
RO
-3921
00 02
code Selection of Area code of inverter RO
-3931
01 15
code Selection of Capacity code of inverter RO
- 394 1 00,01 code Selection of Voltage of inverter RO
- 395 1 00,01 code Selection of Changeover of inverter mode RO
d001 397 4
0 400.000Hz
*1000 Output frequency RO
d004 398 4
0 400.000Hz
*1000 Feedback data of PID control RO
d007 399 4
0 39960.000
*1000 Value of conversion of frequency RO
d101 400 4
0 400.000Hz
*1000 Output frequency after Vector control RO
d016 401 4
0
4294836225s
*1 Accumulated time during running RO
d017 402 4
0
4294836225s
*1 Accumulated time during Power ON RO
-4034
0 400.000Hz
*1000 Setting frequency from terminal RO
-4044
0 400.000Hz
*1000
Setting frequency from
attached potentiometer
RO
-4054
0 400.000Hz
*1000 Setting frequency from digital operator RO
d002 407 2
0 1000.0A
*10 Output current RO
d005 408 2
0 H'FFFF
bit Status of Input terminal RO
d012 409 2
-300 +300%
*1 Output Torque No RO
d014 410 2
0 1000.0kW
*10 Input electric power RO
412 2
0 1000.0V
*10 DC voltage
RO
413 2
0 100.0s
*10 On time of BRD running RO
414 2
0 100.0%
*10 Used rate of electronics thermal protection RO
d006 416 2
0 H'FFFF
bit Status of output terminal RO
d013 417 2
0 1000.0V
*10 Output voltage RO
d003 418 1
00 02
code Direction of present running
RO
R/W: Parameter is read/writable.
R/WOS: Parameter is readable, but can only be written when the inverter is stopped.
R/O: Parameter is read-only. Cannot be written.