Diagnostic Error Code FRU/Action
000-197-XXX
BIOS test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
000-198-XXX
BIOS test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to the
“Undetermined
problem” section.
000-199-XXX
BIOS test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test.
3. Replace component
under function test.
000-250-XXX
BIOS APM failure
1. Flash the system
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system
2. System board
001-000-XXX
System Test Passed
1. No action
001-00X-XXX
System Error
1. System board
001-01X-XXX
System Error
1. System board
001-024-XXX
System Addressing test
failure
1. System board
001-025-XXX
System Checksum Value
error
1. Flash the system
2. System board
001-026-XXX
System FLASH data error
1. Flash the system
2. System board
001-027-XXX
System Configuration/Setup
error
1. Run Setup
2. Flash the system
3. System board
001-032-XXX
System Device Controller
failure
1. System board
001-034-XXX
System Device Buffer
Allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
2 IBM PC 300/IntelliStation Vol 3 HMM