POST Error Code FRU/Action
1117
Failed baud rate test.
1. Run Enhanced
Diagnostics
1162
Serial port configuration
error.
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
11XX
Not listed above.
1. System Board
1201 1. System Board
2. Any Serial Device
1202, 1206, 1208,
1209, 12XX
1. Dual Async
Adapter/A
2. System Board
3. Any Serial Device
1207 1. Communications
Cable
2. Dual Async Adapter/A
13XX 1. Game Adapter
1402
Printer not ready.
Information only
1403
No paper error, or
interrupt failure.
Information only
1404
System board timeout
failure.
1. Run Enhanced
Diagnostics
1405
Parallel adapter error.
1. Run Enhanced
Diagnostics
1406
Presence test error.
1. Run Enhanced
Diagnostics
14XX
Not listed above.
Check printer before
replacing system board.
1. Printer
2. System Board
15XX 1. SDLC Adapter
1692
Boot sequence error.
1. Run FDISK to ensure
at least one active
partition is set active.
16XX 1. 36/38 Workstation
Adapter
1762
Hard disk drive configuration
error.
1. Run Configuration
(See “Setup Utility
program” on
page 241.)
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
1. See “Power supply”
on page 229.
2. Hard Disk Drive
3. System Board
4. Riser card
5. Hard Disk Cable
6. Power Supply
IntelliStation - 6867 281