IBM 6584 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
217-000-XXX
Hard Disk Drive Test
Passed
1. No action
217-25X-XXX
217-26X-XXX
Hard Disk Drive (IDE) error
1. Hard Disk Drive
Cable
2. Check power supply
voltages
3. Hard Disk drive (IDE)
4. System board
217-28X-XXX
217-29X-XXX
Hard Disk Drive (SCSI)
error
1. Hard Disk Drive
Cable
2. Check power supply
voltages
3. Hard Disk drive (SCSI)
4. SCSI adapter card
5. System board
220-000-XXX
Hi-Capacity Cartridge Drive
Test Passed
1. No action
220-XXX-XXX
Hi-Capacity Cartridge Drive
error
1. Remove the
Hi-Capacity Cartridge
Drive and re-test the
system
301-000-XXX
Keyboard Test Passed
1. No action
301-XXX-XXX
Keyboard error
1. Keyboard
2. Check and test Mouse
3. System board
302-000-XXX
Mouse Test Passed
1. No action
302-XXX-XXX
Mouse error
1. Mouse
2. Check and test
Keyboard
3. System board
303-000-XXX
Joystick Test Passed
1. No action
303-XXX-XXX
Joystick error
1. Remove the Joystick
and re-test the
system
305-000-XXX
Monitor DDC Test Passed
1. No action
305-250-XXX
Monitor DDC self test failure
1. Run Setup to enable
DDC
2. Cable
3. Monitor
4. Video card
5. System board
415-000-XXX
Modem Test Passed
1. No action
415-XXX-XXX
Modem error
1. Remove the Modem
and re-test the
system
20 IBM PC 300/IntelliStation Vol 3 HMM