Message Failure Found Recommended
Actions
2xx-2y
(for
DIMMs/RIMMs)
A memory error
was detected in
DIMM/RIMM pair
socket Y
Replace the
DIMM/RIMM in
the pair sockets
identified by the
last digit of the
error code one at
a time.
Re-run the test.
If the same error
code occurs
again, replace
both of the RIMM
pair.
If the same error
code occurs
again, replace
the memory
board or where
memory is on the
processor card,
replace the
processor card.
Corrupt BIOS Information in
BIOS is not as
expected.
Not able to find
expected DMI
information from
BIOS.
Memory controller
chipset vendor ID
does not match
expected value.
Reflash the
BIOS.
Perform boot
block recovery.
Replace the
system board.
Test aborted by
user
User stopped
test.
Restart test.
Note:
"Y" is the SIMM/DIMM/RIMM socket number. Use the
System Board memory section to reference the memory
sockets.
IntelliStation - 6866 139