Diagnostic Error Code FRU/Action
011-197-XXX
Serial port test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
011-198-XXX
Serial port test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
011-199-XXX
Serial port test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
011-2XX-XXX
Serial port signal failure
1. External serial device
2. System board
014-000-XXX
Parallel port Interface Test
Passed
1. No action
014-001-XXX
Parallel port Presence
1. Remove external
parallel device, if
present
2. Run setup, enable port
3. System board
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity
error
1. System board
014-013-XXX
014-014-XXX
Parallel port Control
Signal/Loopback test failure
1. System board
014-015-XXX
Parallel port External
Loopback failure
1. Wrap plug
2. System board
014-027-XXX
Parallel port
Configuration/Setup error
1. Run Setup, enable
port
2. Flash the system
3. System board
014-03X-XXX
014-04X-XXX
Parallel port failure
1. System board
014-195-XXX
Parallel port Test aborted by
user
1. Information
2. Re-start the test, if
need to
8 IBM PC 300/IntelliStation Vol 3 HMM