Diagnostic Error Code FRU/Action
006-198-XXX
Diskette interface test
aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
006-199-XXX
Diskette interface test failed,
cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
006-25X-XXX
Diskette interface Error
1. Diskette drive Cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test
Passed
1. No action
011-001-XXX
Serial port Presence
1. Remove external
serial device, if
present
2. Run setup, enable port
3. System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parity
error
1. System board
011-013-XXX
011-014-XXX
Serial port Control
Signal/Loopback test failure
1. System board
011-015-XXX
Serial port External
Loopback failure
1. Wrap plug
2. System board
011-027-XXX
Serial port
Configuration/Setup error
1. Run Setup, enable
port
2. Flash the system
3. System board
011-03X-XXX
011-04X-XXX
Serial port failure
1. System board
011-195-XXX
Serial port Test aborted by
user
1. Information
2. Re-start the test, if
need to
011-196-XXX
Serial port test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
IBM PC Enhanced Diagnostics error codes 7