Diagnostic Error Code FRU/Action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if
installed
4. System board
035-195-XXX
RAID interface Test aborted
by user
1. Information
2. Re-start the test, if
need to
035-196-XXX
RAID interface test halt,
error threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
035-197-XXX
RAID interface test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
035-198-XXX
RAID interface test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
035-199-XXX
RAID interface test failed,
cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
071-000-XXX
Audio port Interface Test
Passed
1. No action
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error
1. Run Setup
2. Flash the system
3. System board
071-03X-XXX
Audio port failure
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
071-04X-XXX
Audio port failure
1. Run Setup
2. Audio card, if installed
3. System board
071-195-XXX
Audio port Test aborted by
user
1. Information
2. Re-start the test, if
need to
14 IBM PC 300/IntelliStation Vol 3 HMM