IBM 6584 Personal Computer User Manual


 
Select Utility
Select Asset EEPROM Backup
follow instructions on screen.
Viewing the test log
Errors reported by the diagnostic test will be displayed by
the program as a failed test.
To view details of a failure or to view a list of test results,
do the following from any test category screen:
Press F3 to activate the log File
Press F3 again to save the file to diskette or F2 to
print the file.
RIMM memory errors: SIMM/DIMM/RIMM error
messages issued by the IBM PC Enhanced Diagnostics:
Message Failure Found Recommended
Actions
2xx-1y
(for SIMMs)
A memory error
was detected in
SIMM socket Y
Replace the
SIMM in the
socket identified
by the last digit of
the error code.
Re-run the test.
If the same error
code occurs
again, replace
the system
board.
2xx-2y
(for
DIMMs/RIMMs)
A memory error
was detected in
DIMM/RIMM
socket Y
Replace the
DIMM/RIMM in
the socket
identified by the
last digit of the
error code.
Re-run the test.
If the same error
code occurs
again, replace
the system board
or where memory
is on the
processor card,
replace the
processor card.
IntelliStation - 6867 239