Feature Description
Size Depth: 445 mm (17.5 inches)
Height: 492 mm (19.4 inches)
Width: 200 mm (7.9 inches)
Weight Weight: 17.3 kg (38 lb)
Fully configured
4
Environment Air temperature:
- System on: 10° to 35°C
(50° to 95°F)
- System off: 10° to 50°C
(50° to 122°F)
Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
Maximum altitude: 3048 m (10,000 ft)
Heat Output Approximate heat output in BTUs per
hour:
- Minimum: 245 BTU (70 watts)
- Maximum: 969 BTU (285 watts)
5
Electrical Input Sine-wave input (47 to 63 Hz) required.
Low range input voltage:
- Minimum: 90 V ac
- Maximum: 137 V ac
High range input voltage:
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kVA (approximately):
- Maximum (as shipped): 0.08 kVA
Airflow Approximately 0.56 cubic
meters/minute (20 CFM)
Acoustical
Noise Emission
Values
Average sound pressure levels:
At operator position:
- 35 dB operating
- 33 dB idle
At bystander position (1 meter):
- 32 dB operating
- 29 dB idle
Declared (upper limit) sound power
levels:
- 4.8 bels operating
- 4.5 bels idle