POST Error Code FRU/Action
101XX
Not listed above.
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
4. Riser card
10450, 10451, 10490
10491, 10492, 10499
Read/write error.
1. Run Enhanced
Diagnostics
2. Hard Disk Drive
3. System Board
4. Riser card
10452
Seek test error.
1. Run Enhanced
Diagnostics
10453
Wrong drive type?
Information only
10454
Sector buffer test error.
1. Run Enhanced
Diagnostics
10455, 10456
Controller error.
1. Run Enhanced
Diagnostics
10459
Drive diagnostic command
error.
Information only
10461
Drive format error
1. Run Enhanced
Diagnostics
10462
Controller seek error.
1. Run Enhanced
Diagnostics
10464
Hard Drive read error.
1. Run Enhanced
Diagnostics
10467
Drive non fatal seek error.
1. Run Enhanced
Diagnostics
10468
Drive fatal seek error.
1. Run Enhanced
Diagnostics
10469
Drive soft error count
exceeded.
1. Run Enhanced
Diagnostics
10470, 10471, 10472
Controller wrap error.
1. Run Enhanced
Diagnostics
10473
Corrupt data. Low level
format might be required.
Information only
10480 1. Hard Disk Drive
(ESDI)
2. Drive Cable
3. System Board
10481
ESDI drive D seek error.
1. Run Enhanced
Diagnostics
10482
Drive select
acknowledgement bad.
1. Run Enhanced
Diagnostics
106X1 1. Check Configuration
2. Ethernet Adapter
IntelliStation - 6867 285