IBM 6866 Personal Computer User Manual


 
IBM PC Enhanced Diagnostics error
codes
Refer to the following Diagnostic Error Codes when using
the IBM PC Enhanced Diagnostics test. See “Diagnostic
and test information” section for information about the IBM
PC Enhanced Diagnostics program.
In the following index, “X” can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX
BIOS Test Passed
1. No action
000-002-XXX
BIOS Timeout
1. Flash the system
2. System board
000-024-XXX
BIOS Addressing test failure
1. Flash the system
2. System board
000-025-XXX
BIOS Checksum Value error
1. Flash the system
2. Boot block
3. System board
000-026-XXX
FLASH data error
1. Flash the system
2. Boot block
3. System board
000-027-XXX
BIOS Configuration/Setup
error
1. Run Setup
2. Flash the system
3. Boot block
4. System board
000-034-XXX
BIOS Buffer Allocation
failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition
detected
1. Flash the system
2. System board
000-036-XXX
BIOS Register error
1. Flash the system
2. Boot block
3. System board
000-038-XXX
BIOS Extension failure
1. Flash the system
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1. Flash the system
2. System board
000-195-XXX
BIOS Test aborted by user
1. Information
2. Re-start the test, if
need to
000-196-XXX
BIOS test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
Copyright IBM Corp. 2000 1