Select Utility
Select Asset EEPROM Backup
follow instructions on screen.
Viewing the test log
Errors reported by the diagnostic test will be displayed by
the program as a failed test.
To view details of a failure or to view a list of test results,
do the following from any test category screen:
Press F3 to activate the log File
Press F3 again to save the file to diskette or F2 to
print the file.
RIMM memory errors: SIMM/DIMM/RIMM error
messages issued by the IBM PC Enhanced Diagnostics:
Message Failure Found Recommended
Actions
2xx-1y
(for SIMMs)
A memory error
was detected in
SIMM socket Y
Replace the
SIMM in the
socket identified
by the last digit of
the error code.
Re-run the test.
If the same error
code occurs
again, replace
the system
board.
2xx-2y
(for
DIMMs/RIMMs)
A memory error
was detected in
DIMM/RIMM
socket Y
Replace the
DIMM/RIMM in
the socket
identified by the
last digit of the
error code.
Re-run the test.
If the same error
code occurs
again, replace
the system board
or where memory
is on the
processor card,
replace the
processor card.
PC 300 - 6584/6594 39