IBM 6866 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
015-035-XXX
USB port Reset condition
detected
1. Remove USB
Device(s) and re-test
2. System board
015-036-XXX
USB port Register error
1. System board
015-040-XXX
USB port IRQ failure
1. Run setup and check
for conflicts
2. Flash the system
3. System board
015-195-XXX
USB port Test aborted by
user
1. Information
2. Re-start the test, if
need to
015-196-XXX
USB port test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
015-197-XXX
USB port test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
015-198-XXX
USB port test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
015-199-XXX
USB port test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
018-000-XXX
PCI Card Test Passed
1. No action
018-0XX-XXX
PCI Card Failure
1. PCI card
2. Riser card, if installed
3. System board
018-195-XXX
PCI Card Test aborted by
user
1. Information
2. Re-start the test, if
need to
018-196-XXX
PCI Card test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
10 IBM PC 300/IntelliStation Vol 3 HMM